Generic filters
Exact matches only
FS Logoi

Rehabilitation of large profiles lacking long-term stability

Thema:

Publikationsform: Fachartikel
Artikelnummer: 01252_2016_SP2_01
Zeitschrift: Rehabilitation of large profiles lacking long-term stability
Erscheinungsdatum: 01.01.1970
Autor: Dietmar Beckmann / Heinz Doll / Vladimir Lacmanović
Herausgeber: Many large interceptor sewers, predominantly installed under public roads, have been in use for over 100 years. They are made of brickwork or compressed concrete and often show serious damage, so that it would seem that long-term stability can no longer be guaranteed. As an alternative to replacing large profiles, various renovation procedures offer significant advantages with respect to investment costs, environmental protection and urban pollution. Depending on the procedure, it may well be possible to extend the service life, in order to match that of a replacement. However, beforehand, an in-depth study of the current stability and residual load capacity of the existing sewer is required, along with needs-based selection and dimensioning of the rehabilitation procedure. The new standard DWA-A 143-2 serves as a good basis for the necessary static calculations.
Verlag: Vulkan-Verlag GmbH
Publikationsformat: PDF
Themenbereich:

Details

Many large interceptor sewers, predominantly installed under public roads, have been in use for over 100 years. They are made of brickwork or compressed concrete and often show serious damage, so that it would seem that long-term stability can no longer be guaranteed. As an alternative to replacing large profiles, various renovation procedures offer significant advantages with respect to investment costs, environmental protection and urban pollution. Depending on the procedure, it may well be possible to extend the service life, in order to match that of a replacement. However, beforehand, an in-depth study of the current stability and residual load capacity of the existing sewer is required, along with needs-based selection and dimensioning of the rehabilitation procedure. The new standard DWA-A 143-2 serves as a good basis for the necessary static calculations.

Preis: 4,90 €Zum Shop

Infos zum Autor/Verfasser/Herausgeber

Publikationen zum selben Thema

Datenschutz
3r-rohre.de, Inhaber: Vulkan-Verlag GmbH (Firmensitz: Deutschland), würde gerne mit externen Diensten personenbezogene Daten verarbeiten. Dies ist für die Nutzung der Website nicht notwendig, ermöglicht aber eine noch engere Interaktion mit Ihnen. Falls gewünscht, treffen Sie bitte eine Auswahl:
Datenschutz
3r-rohre.de, Inhaber: Vulkan-Verlag GmbH (Firmensitz: Deutschland), würde gerne mit externen Diensten personenbezogene Daten verarbeiten. Dies ist für die Nutzung der Website nicht notwendig, ermöglicht aber eine noch engere Interaktion mit Ihnen. Falls gewünscht, treffen Sie bitte eine Auswahl: